ICx Technologies Home
Specifications
Gamma Eight (8) 1 cm3 CdZnTe solid state detectors
ID Resolution <3.5 % at 662 keV
Detection Sensitivity ≥ 6 cps/μR/h for Cs137
ID Sensitivity ≥ 0.75 cps/μR/h for Cs137
ID Energy Range 25 KeV to 3 MeV
Dose rate energy range 50 keV to 3 MeV
Dose rate Range 5 μR/h to 5 R/h
Throughput >100 k cps
Spectrum memory 2048 channels
Neutron Two (2) He3 detectors, 0.5” by 1.62” @ 15 atm.
Energy Range Thermal to 10 MeV
Sensitivity 6 cps/nv ± 20%
Flux range 1.3*10-3 to 3.74*104 nv
Alarm Levels Three (3) gamma, two (2) neutron, adjustable
Display Primary 3.5” TFT LCD, 240 W x 320 H pixels, 64 k colors
Secondary OLED display of dose rate and neutron cpm
Protection Class IP67
GPS Built in sensor
Reach-back via Bluetooth
Batteries Primary; Three (3) AA NiMH or Alkaline, up to 2.7 Ah capacity, built-in charger
Secondary; Internal rechargeable Polymer Li-Ion, 0.6 AhLow battery notification at 20%, alarm at 4%
External Power PC USB or 1.5V/1.5A from external supply (provided)
Operating Time Up to 65 h in Surveillance mode;
Up to 10 h in Finder mode;
Up to 6.5 h in Spectroscopy mode
All dependent on battery type used and charge status
Charging Time 5 to 12 h, depending on battery status and power supply
Interfaces USB 2.0, Bluetooth©
Camera 640 x 480 pixels
Weight 1.4 lbs (650 g)
Dimensions 5.9” x 3.35” x 2”, (150 x 85 x 50 mm)
Temperature Range -4°F to +122°F (-20 °C to +50 °C)
Memory 4 Gigabyte solid state memory
Operation Four (4) buttons to operate plus one (1) for power
Web Server Interface For remote monitoring and configuration of Raider